Air humidity meter / Sintered hood to protect against moisture and dust / Data reading on any PC / Memory for about 50000 values / CSV format / Micro USB rechargeable battery / Easy handling
The air humidity meter is a mobile device for controlling the quality of compressed air in mobile and fixed-installation air pressure generators. This air humidity meter measures temperature, relative humidity, H2O and calculates the current dew point with a pressure of 20 bar.
The memory allows recording the parameters of a pressure pipe for a certain time space. The values are stored in the internal memory of the air humidity meter. It is possible to read the values recorded in the air humidity meter itself. It can also connect the dew point meter to a computer

- Data storage with export in CSV
- Root point, H2O, temperature, humidity
- For measurement in pressure tubes
- Accumulator for mobile use
- With a G 1/2" connecting thread
- Sensor is protected by sintered hood


   
The following is the list of the parameters: The temperature
Rate -10 ... 60 °C
Resolution adopted by the Council 0,01 °C
Precision at 20 °C -10 ... 50 °C: ±0,3 °C
   
The following is the list of the parameters: Relative humidity
Rate 0 ... 100%
Resolution adopted by the Council 0,01 %
Precision at 20 °C Other:
  ±(0,025 % + 17,5% of the value)
  > 5%: ±(1 % + 5 % of the value)
  > 15%: ±(2 % + 3 % of the value)
   
The following is the list of the parameters: Roost point*
Rate -50 ... 30 °C
Resolution adopted by the Council 0,01 °C
Accuracy -40 ... 20 °C: ±2 °C
  -50 ... -40 °C: ±2,5 °C
*The accuracy of the dew point is applicable with a
ambient temperature between 16 ... 25 °C
   
The following is the list of the parameters: H2O
Rate 40 ... 20,000 ppm
Resolution adopted by the Council 1 ppm
Precision at 20 °C The following table shows the results of the calculation:
   
Environmental conditions -10 ... 60 °C
  0 ... 20 bar (absolutely)
The following conditions shall apply: The following conditions shall apply:
20 °C, 63% H.r.[90%) -40 ... 0 °C: 10s [20s]
   
Memory For approximately 50,000 values
Registration fee 10 seconds
  1, 5, 10, 20, minutes
Time of recording The following shall be added to the list of the following:
The following table summarizes the information: The following is the list of the countries of the European Union:
Length of cable About five feet.
Roasted G1/2 '
Tossed length 1.2 cm
Longitude of probe 5,2 cm
Wide probe 1.2 cm
Screen LCD of 2,3"
Accumulative power Other electrical equipment
Power supply adapter network
  Input: 100 ... 240 VAC, 0,25 A
  Out: 5 VDCs, 1 A
Interface Other electrical equipment
Weight Approximately 610 g
   