The power analyzer is a table instrument that measures actual power, apparent power, power factor, energy consumption, current and alternating voltage, current and continuous voltage, resistance and frequency. Its large, easy-to-read LCD screen and 93 x 52 mm provides various results at once
- Multi-meter function
- Direct current measurement by connecting a touch head or a current clamp
- Measurement of effective and apparent power
- Measurement of the power factor
- Measurement of energy consumption (kWh)
- Value maintenance / peak value
- Hold function / Alarm function High / Low
- RS-232 interface
- Power by grid or battery
- Safety: IEC-1010-1; CAT II 600 V
The image shows the PCE-PA-ADP optional current adapter
The above images show the analysis software that is sent with the power analyzer. 4 measurement values can be represented at a time and the graphic indicator allows for comfortable long-term recordings that can be evaluated afterwards.
- Direct current measurement by connecting a touch head or a current clamp
- Measurement of effective and apparent power
- Measurement of the power factor
- Measurement of energy consumption (kWh)
- Value maintenance / peak value
- Hold function / Alarm function High / Low
- RS-232 interface
- Power by grid or battery
- Safety: IEC-1010-1; CAT II 600 V
The image shows the PCE-PA-ADP optional current adapter
The above images show the analysis software that is sent with the power analyzer. 4 measurement values can be represented at a time and the graphic indicator allows for comfortable long-term recordings that can be evaluated afterwards.
| Measurement of actual power (AC, real value power), direct measurement | |
| Measurement range | 1 W ... 6 kW |
| Resolution adopted by the Council | Other, not further worked than hot-rolled Other, of a kind used for the manufacture of goods |
| Accuracy | ±1,5% + 1 dgt |
| Measurement of actual power (AC, real value power), with extended adapter or current converter | |
| Measurement range | 1 W... 999.99 kW |
| Resolution adopted by the Council | ... 999.9 W: 0.1 W ... 9,999 W: 1 W ... 99,99 kW: 0,01 kW ... 999.99 kW: 0,1 kW |
| Accuracy | ±1,5% + 1 dgt |
| Measurement of apparent power (AC) | |
| Measurement range | The value of the goods shall be the value of the goods. |
| Resolution adopted by the Council | ... 99.9 VA: 0.01 VA ... 999.9 VA: 0.1 VA ... 9.999 VA: 1 VA |
| Accuracy | ± 2 % + 2 dgt. |
| Power factor (cos φ) | |
| Measurement range | 0,00... 1,00 |
| Resolution adopted by the Council | 0,01 |
| Accuracy | ±1,5% + 2 dgt. |
| Counter of KWh | |
| Measurement range | The following conditions shall apply: |
| Resolution adopted by the Council | 0,001 ... 9,999 Wh: 0,001 Wh 0,01 Wh The following conditions shall apply: 1000 ... 9999 Wh: 1 Wh 10 K ... 99.99 K Wh: 10 Wh 100 K ... 999.9 K Wh: 100 Wh 1000 K ... 9999 K Wh: 1 K Wh |
| Accuracy | ±1,5% + 2 dgt. |
| The following conditions shall apply: | |
| Measurement range | The following conditions shall apply: |
| Resolution adopted by the Council | 0,1 ... 299,9 V: 0,1 V 300 ... 600 V: 1 V |
| Accuracy | The following is the list of the following: The following conditions shall apply: The following conditions shall apply: ACV (other ranges): ±1 % + 1 dgt |
| ACA eff/rms / DCA eff/rms, direct measurement | |
| Measurement range - ACA eff/rms - DCA eff/rms | 0,05 ... 10 A 0,01 ... 10 A |
| Resolution adopted by the Council - ACA eff/rms - DCA eff/rms | 0,05 ... 1,999 A: 1 mA 2,00 ... 10,00 A: 10 mA 0,01 ... 10,00 A: 10 mA |
| Accuracy - ACA eff/rms - DCA eff/rms | ± 1 % + 3 dgt. ± 1 % + 1 dgt. |
| ACA eff/rms / DCA eff/rms, with adapter | |
| Measurement range - ACA eff/rms - DCA eff/rms | 1 ... 1000 A 1 ... 1000 A |
| Resolution adopted by the Council - ACA eff/rms - DCA eff/rms | < 20 A: 0,01 A 20 ... 199.9 A: 0.1 A 200 ... 1000 A: 1 A 1000 A: 1 A |
| Accuracy - ACA eff/rms - DCA eff/rms | ± 1 % + 3 dgt. ± 1 % + 1 dgt. |
| ACA with tweezers | up to 2000 A (according to the clamp) |
| Frequency | |
| Measurement range | The frequency of the signal is: |
| Resolution adopted by the Council | 10 ... 99,9 Hz: 0,1 Hz 100 ... 999 Hz: 1 Hz |
| Accuracy | ± 1 % + 1 dgt. |
| Ohm, what's that? | |
| Measurement range | 1 Ω... 19.99 kΩ |
| Resolution adopted by the Council | 0 ... 9,999 Ω: 1 Ω 10 ... 19,99 kΩ: 10 Ω |
| Accuracy | ± 1 % + 1 dgt. |
| General technical specifications | |
| Screen | Multifunctional LCD of 93 x 52 mm |
| Environmental conditions | Max. 80 % H.r. / 0 ... +50 °C |
| Food | 6 x 1,5 V AA batteries or with a network adapter |
| Dimension | Other, of a thickness of not more than 10 mm |
| Weight | Other, of a kind used for the manufacture of goods |