Amplifier, Cable, Head Unit, NPN

Amplifier, Cable, Head Unit, NPN

Model

LV-N11N

Type

2 Outputs

Emission

NPN

Cable/Connector

Cable

Main Unit/Expansion

Main Unit

I/O

Control Outputs

2 Outputs

External Input

1 Input

Monitor Output

None

Response Time

80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1

Output Selection

Activated by light (LIGHT-ON)/activated by darkness (DARK-ON) (selectable by switch)

Timer Function

  • Timer deactivated (OFF)/Delay timer deactivated (OFF)/Delay timer activated/
  • Single shot timer,
  • Timer duration selection: 1 ms to 9999 ms,
  • Maximum error against the set value: ±10% max.

Control Output

Collector open NPN 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA)

(independent) 1 output max: 100 mA or less, total 2 outputs: 100 mA or less

(multiple connections) 1 output maximum: 20 mA or less.

Monitor Output

-

External Input

Input time 2 ms (ON)/20 ms (OFF) or more *2

Multiple Connections to Expansion Units

It is possible to connect a maximum of 17 units in total (the two-output model is considered as two units)

Protection Circuit

Reverse polarity protection, overload protection, wave absorber

Number of Interference Prevention Units

  • Connected to another different from LV-S31: 0 for HIGH SPEED; 2 for FINE/TURBO/SUPER; 4 for ULTRA/MEGA,
  • Connected to LV-S31: 2 for FINE; 4 for TURBO/SUPER/ULTRA/MEGA *3

Cover Size

Height 32.6 mm (1.28") × Width 9.8 mm (0.39") × Length 78.7 mm (3.1")

Nominal Value

Power Supply Voltage

From 24 VCD (working voltage 10 - 30 VCD (with fluctuation)), ripple (P-P) 10% or less, Class 2 or LPS *4

Operating Condition

Power Consumption

  • Normal: 830 mW or less (at 30 V . 30 mA at 24 V, 56 mA or less at 12 V) *5
  • Eco Mode On: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V) *5
  • Eco Full Mode: 550 mW or less (at 30 V . 21 mA at 24V, 40 mA or less at 12 V) *6

Ambient Resistance

Temperature

From -20 to +55 °C (-4 to +131 °F) (Without freezing) *7

Relative Humidity

35 to 85% HR (Without condensation)

Vibration Resistance

10 to 55 Hz, Double Amplitude 1.5 mm (0.06"), 2 hours in each of the X, Y and Z directions

Shock Resistance

500 m/s² , 3 times in each of the X, Y and Z directions

Material

  • Cable: PVC
  • Cover: Main unit and cover material: Polycarbonate

Weight

Approx. 75 g

*1 80 µs cannot be selected when LV-S31/S62/S63 is connected.* *2 The input time is 25 ms (ON)/25 ms (OFF) when the external calibration time is selected.* *3 The numbers are doubled when "DOUBLE" is selected.* *4 To connect more than 9 units, the voltage must be 20 V or more.* *5 Increases by 30 mW (1 mA) for high-speed mode.* *6 Increases by 15% when connected to LV-NH100/NH110/NH300. This does not include the power consumption of the load. The power consumption when expansion units are connected is the total consumption of each amplifier. Example: When a main unit (LV-N11N) is connected to two expansion units (LV-N12N) and these are used with LV-NH100 heads in HIGH SPEED mode. (1.15 x 860 mW x 1) + (1.15 x 860 mW x 2) = 2967 mW max.* *7 When used together more than one unit, the ambient temperature varies with the conditions mentioned below. Install the units on the DIN rail with the mounting hardware and check that the output current is less than or equal to 20 mA for each unit. One or two units connected: from -20 to +55 °C (-4 to +131 °F); 3 to 10 units connected: from -20 to +50 °C (-4 to +122 °F); 11 to 16 units connected: from -20 to +45 °C (-4 to +113 °F). When using 2 outputs, one unit is counted as two units.

Products Related