Sensor heads IL-065 Keyence
Om du vill ha en offert på detta produkten kan du begära det genom att klicka på knappen nedan.
Förfrågning om pris
Model |
IL-065 |
|||
Reference distance |
65 mm 2.56" |
|||
Measurement range |
55 to 105 mm 2.17" to 4.13" |
|||
Light source |
Type |
Red semiconductor laser, wavelength: 655 nm (visible light) |
||
Laser class |
Class 2 (FDA (CDRH) Part1040.10)*1 |
|||
Output |
560 μW |
|||
Spot diameter (at standard distance) |
Approx. 550 × 1750 µm 21.65 x 68.9 Mil |
|||
Linearity |
±0.1% of F.S. (55 to 75 mm 2.17" to 2.95")*2*3 |
|||
Repeatability |
2 µm 0.08 Mil*4 |
|||
Sampling cycle |
0.33/1/2/5 ms (4 levels available) |
|||
Operation status indicators |
Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED |
|||
Temperature characteristics |
0.06% of F.S./°C*3 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Operating ambientluminance |
Incandescent lamp: 7500 lux*5 |
|||
Operating temperature range |
-10 to +50°C 14 to 122°F (No condensation or freezing) |
|||
Operating ambient humidity |
35 to 85% RH (No condensation) |
|||
Vibration |
10 to 55 Hz Double amplitude 1.5 mm 0.06" XYZ each axis: 2 hours |
|||
Pollution degree |
3 |
|||
Material |
Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 75 g |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50. |