1), then Kn = (2.7644 * P1 - 1000) / (3.324 * P1 - 1061), else Kn = 1.0 Calculate Capacity of Selected Valve W 19486,799 kg/hr 19486,799 kg/hr W = 52.5 * A * P1 * K * Kb * Kc * Kn * Ksh * Ksc Calculate Required Orifice Area Areq Areq = A * Wreq / W Printed On: 8-jun.-2021 PRV²SIZE Software Version pr7_20200901.1 Page : 2 Emerson Automation Solutions and its parent, subsidiaries, and affiliates assume no liability in any way whatsoeve "> Crosby LAB70AA191(*) 1.5G2.5 HSJ-66-C 1 1/2" 1500RF x 2 1/2" 300RF Conventional Direct Spring Op | Crosby LAB70AA191(*) 1.5G2.5 HSJ-66-C 1 1/2" 1500RF x 2 1/2" 300 1), then Kn = (2.7644 * P1 - 1000) / (3.324 * P1 - 1061), else Kn = 1.0 Calculate Capacity of Selected Valve W 19486,799 kg/hr 19486,799 kg/hr W = 52.5 * A * P1 * K * Kb * Kc * Kn * Ksh * Ksc Calculate Required Orifice Area Areq Areq = A * Wreq / W Printed On: 8-jun.-2021 PRV²SIZE Software Version pr7_20200901.1 Page : 2 Emerson Automation Solutions and its parent, subsidiaries, and affiliates assume no liability in any way whatsoeve ">

(+34) 951 152 505 | info@adjditec.com

ADJ DiTec Málaga S.L
  • Hlavný
  • Spoločnosť
    • Politika rovnosti
    • Politika dodávateľov
    • Ochrana životného prostredia
    • Ekologická zodpovednosť
    • Legálny.
    • Ochrana údajov
  • Služby
  • Produkty
    • Likvidácia
    • Výrobcovia
    • Kategórie
    • Katalógy
  • Správy
  • Kontakt
  • Hlavný
  • Produkty
  • 6b20b781-a51d-11ef-864f-5404a6f3ca70

Crosby LAB70AA191(*) 1.5G2.5 HSJ-66-C 1 1/2" 1500RF x 2 1/2" 300RF Conventional Direct Spring Op

Kategória: : Valvulas
Výrobca: Emerson Process
Kód: : Crosby LAB70AA191(*) 1.5G2.5 HSJ-66-C 1 1/2" 1500RF x 2 1/2" 300
Tweet Follow @ADJDiTec
.

Nombre no disponible.

Ak chcete získať ponuku na tento výrobok, kliknite na nasledujúci tlačidlo.

Poprosiť o ceny

Crosby LAB70AA191(*) 1.5G2.5 HSJ-66-C 1 1/2" 1500RF x 2 1/2" 300RF Conventional Direct Spring Op

 

luid Properties Molecular Weight M 18,020 18,020
Ratio of Specific Heats k 1,310 1,310
Inlet Stagnation Enthalpy ho 2667,0 KJ/kg 2667,0 KJ/kg
Process Cond. Required Mass Flow Wreq
Set Pressure Pset 1790,6 psig 123,458 barg
Over Pressure Pover 53,718 psig 3,704 barg
Inlet Line Loss Ploss 0 psig 0 barg
Back Pressure Pback 0 psig 0 barg
Atmospheric Pressure Patm 14,696 psia 1,013 bara
Relieving Temperature T 329,736 °C 602,886 °K
Distance from Valve (noise) r 1 m 1 m
Rupture Disc CCF Kc 1,0 1,0
Superheat Correction Factor Ksh 1,0 1,0
Supercritical Correction Factor Ksc 1.0 1.0
Valve Data Discharge Coefficient (actual) Kd 0,975 0,975
Discharge Coefficient (derated) K 0,878 0,878
Orifice Area A 0,503 in² 3,245 cm²
Back Press. Correction Factor Kb 1,0 1,0
Outlet Diameter Do 63,22 mm 6,32 cm
Calculate Inlet Relieving Pressure, Outlet Pressure, Absolute Pressure Ratio
P1 = Pset + Pover - Ploss + Patm P1 128,175 bara
P2 = Pback + Patm P2 1,013 bara
PR = P2 / P1 PR 0,008
Calculate Napier Correction Factor Kn 1,017
If (103.4 bara ≤ P1 ≤ 220.6 bara) and (Kn > 1), then Kn = (2.7644 * P1 - 1000) / (3.324 * P1 - 1061), else Kn = 1.0

Calculate Capacity of Selected Valve W 19486,799 kg/hr 19486,799 kg/hr
W = 52.5 * A * P1 * K * Kb * Kc * Kn * Ksh * Ksc
Calculate Required Orifice Area Areq
Areq = A * Wreq / W

Printed On: 8-jun.-2021 PRV²SIZE Software Version pr7_20200901.1 Page : 2

Emerson Automation Solutions and its parent, subsidiaries, and affiliates assume no liability in any way whatsoeve


Podobné produkty

  • Zobraziť PODROBNOSŤA
    FLO CONTROL 609500/638 Electroválvula 230V, 13,5VA
    FLO CONTROL 609500/638 Electroválvula 230V, 13,5VA
  • Zobraziť PODROBNOSŤA
    Parker RAH161S30V OVERPRESSURE VALVE
    Parker RAH161S30V OVERPRESSURE VALVE
  • Zobraziť PODROBNOSŤA
    AVENTICS R422103007
    AVENTICS R422103007
  • Zobraziť PODROBNOSŤA
    COMPAIR 100015591 2/2-SOLENOID VALVE NO 230V/50/60Hz; 8W
    COMPAIR 100015591 2/2-SOLENOID VALVE NO 230V/50/60Hz; 8W
  • Zobraziť PODROBNOSŤA
    VÁLVULA ESFERA 1
    VÁLVULA ESFERA 1" NYLON
  • Zobraziť PODROBNOSŤA
    ANTIRRETORNO 6.5 BAR ( 031664 modificado)
    ANTIRRETORNO 6.5 BAR ( 031664 modificado)

Významné produkty
  • Allen-Bradley DISTRIBUTION BOX DC MICRO
    Allen-Bradley DISTRIBUTION BOX DC MICRO
  • AS-S908-110 SCHNEIDER ELECTRIC - CPU ASS908110
    AS-S908-110 SCHNEIDER ELECTRIC - CPU ASS908110
  • 0.MM.RTM.7000 Prometec
    0.MM.RTM.7000 Prometec
  • DSG-03-2B2-D12-N-50 Yuken
    DSG-03-2B2-D12-N-50 Yuken
  • Crouzet BM2R08MV1 Relé de tiempo 0,5s÷10días DPDT 250VCA/8A Ualim 12÷240VCA
    Crouzet BM2R08MV1 Relé de tiempo 0,5s÷10días DPDT 250VCA/8A Ualim 12÷240VCA

Náhodné produkty
  • Sensor de 200A, diámetro 17 mm.
    Sensor de 200A, diámetro 17 mm.
  • GP006127
    GP006127
  • V100 2.6 MW VCS V100 2.6 MW VCS
    V100 2.6 MW VCS V100 2.6 MW VCS
  • V100 2.6 MW VCS V100 2.6 MW VCS
    V100 2.6 MW VCS V100 2.6 MW VCS
  • Caja de conexiones ABB 00846, Termoplástico, Gris, 100mm, 100mm, 50mm, 100 x 100 x 50mm, IP65
    Caja de conexiones ABB 00846, Termoplástico, Gris, 100mm, 100mm, 50mm, 100 x 100 x 50mm, IP65

Poprosiť o ceny

Nombre no disponible.

Súhlasím s podmienkami v súlade s Orgánovým zákonom o ochrane osobných údajov č. 15/1999 zo decembra, informujeme vás, že vaše údaje sú zapísané do databázy spoločnosti ADJ DiTec Málaga S.L., ktorá je riadne zapísaná v Základnom registri Úradu na ochranu osobných údajov Španielska a budú používané len na poskytnutie informácií o našich službách. V žiadnom prípade sa tieto údaje nebudú využívať na iné účely ani sa nebudú poskytovať tretím stranám, v súlade s princípmi ochrany údajov zákona č. 15/1999 zo dňa 13. decembra o ochrane osobných údajov. Ak nechcete dostávať viac obchodných informácií, dajte nám to vedieť touto istou komunikačnou cestou, písomným vyhlásením zaslaným spoločnosti ADJ DiTec Málaga S.L., so sídlom v MALAGA (MALAGA), PSČ 29006, C/ Bodegueros 21, Local 4, alebo e-mailom na adresu info@adjditec.com.Získajte viac informácií o našej politike ochrany osobných údajov

Správa novín

Zadajte svoju e-mailovú adresu na odber.

Registro úspešný! Boli ste pridaný do nášho newsletteru.

Kontakt

  • Adresa Calle Río Sil, 63, 29196 Málaga

  • Telefón (+34) 951 152 505

  • Elektronická pošta info@adjditec.com

Nasledujte nás.

© Autorské právo 2008 - 2025 Všetky práva vyhradené.

Žiadame o súhlas na získanie štatistiky prehliadania vašej navigácie na tejto webovej stránke. Prijať. | Viac informácií