Cortina de Luz de Seguridad GL-S32SH Keyence

Category: : Seguridad industrial
Manufacturer: Keyence
Code: : GL-S32SH
Tweet Follow @ADJDiTec
.

Nombre no disponible.

If you would like a quote for this product, please click the following button.

REQUEST QUOTES

Model

GL-S32SH

Type

Slim type

Beam axis spacing

20 mm 0.79"

Detection capability

ø25 mm ø0.98"

Operating distance

0.1 to 2 m 0.3' to 6.6'

Effective aperture angle

Max. ±3.75° (when the operating distance is 2 m 6.6')

Light source

Infrared LED (870 nm)

Response time(ms)

Wire synchronization, one-line, or optical synchronization system (channel 0)

ON→OFF

7.9*1

OFF→ON

50.6*2

Optical synchronization system (channel A or B)

ON→OFF

10.9*1

OFF→ON

55.1*2

OSSD operation

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or wire synchronization
(determined by the wiring)

Light interference prevention function

Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output (OSSD output)

Output type

2 transistor outputs
(PNP or NPN output is determined by the cable type.)

Max. load current

Max. 300 mA

Residual voltage (when ON)

Max. 2.5 V (with a cable length of 5 m 16.4')

OFF state voltage

Max. 2.0 V (with a cable length of 5 m 16.4')

Leakage current

Max. 200 µA

Max. load capacitance

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Inputs 1 and 2

Short-circuit current: approx. 1 mA

Power supply

Power supply voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current consumption(mA)

When the center indicator is ON

Transmitter

45*3

Receiver

70*3

When the center indicator is OFF

Transmitter

29*3

Receiver

53*3

Protection circuit

Reverse current protection, short-circuit protection and surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1(Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2(Type 4 AOPD)
IEC61508, EN61508( SIL3), IEC62061, EN62061(SIL CL3)
EN ISO13849-1:2015(Category 4, PLe)
UL508, UL1998
GB4584

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

Ⅱ

Ambient temperature

-10 to +50°C 14 to 122°F (no freezing)

Ambient temperature for storage

-25 to +60°C -13 to 140°F (no freezing)

Relative humidity

15 to 85% RH (no condensation)

Storage relative humidity

15 to 95% RH

Operating ambientluminance

Incandescent lamp: 3000 lux or less
Sunlight: 20000 lux or less

Vibration

10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100m 328.1'/S2 (approx. 10 G), 16 ms pulse 1000 times in each of the X, Y, and Z directions

Material

Main unit case

Polyarylate

Weight

Transmitter

245 g

Receiver

250 g

*1 If the response time (ON to OFF) exceeds 20 ms, this unit cannot be used as a certified product based on the Chinese standard GB 4584 “压力机用光电保护装置技术条件”. * When the GL-S units are connected in series, the response time is calculated according to the following steps;
1. Sum up the response time of all unit.
2. Subtract the following time from the result of previous step.

■ ON→OFF
One sub unit connected: 2 ms
Two sub units connected: 4.2 ms
(When using Optical synchronization system and Channel A or B)
One sub unit connected: 2.7 ms
Two sub units connected: 5.7 ms

■ OFF→ON
One sub unit connected: 42 ms
Two sub units connected: 84 ms

*2 If the response time (ON to OFF) exceeds 20 ms, this unit cannot be used as a certified product based on the Chinese standard GB 4584 “压力机用光电保护装置技术条件”. * When the GL-S units are connected in series, the response time is calculated according to the following steps;
1. Sum up the response time of all unit.
2. Subtract the following time from the result of previous step.

■ ON→OFF
One sub unit connected: 2 ms
Two sub units connected: 4.2 ms
(When using Optical synchronization system and Channel A or B)
One sub unit connected: 2.7 ms
Two sub units connected: 5.7 ms

■ OFF→ON
One sub unit connected: 42 ms
Two sub units connected: 84 ms
If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 The control output (OSSD) current is not included. When inputs are turned ON, the current consumption increases by 1 mA per input.

 


Similar Products

  • SHOW. DETAILS
    Control de seguridad Omron CS1G-CPU43H
    Control de seguridad Omron CS1G-CPU43H
  • SHOW. DETAILS
    783100 Pilz - PNOZ m1p/m0p/m2p
    783100 Pilz - PNOZ m1p/m0p/m2p
  • SHOW. DETAILS
     MA 21 100 - Connection unit 50030481 Leuze
    MA 21 100 - Connection unit 50030481 Leuze
  • SHOW. DETAILS
    KTR HSS COUPLING FOR G47 50 Hz KTR HSS COUPLING FOR G47 50 HZ
    KTR HSS COUPLING FOR G47 50 Hz KTR HSS COUPLING FOR G47 50 HZ
  • SHOW. DETAILS
    LINEA-DE-VIDA-MOVIL-20M-EN795-B
    LINEA-DE-VIDA-MOVIL-20M-EN795-B
  • SHOW. DETAILS
    Control de seguridad Omron CS1D-DPL01
    Control de seguridad Omron CS1D-DPL01

Featured Products
  • Regulador de caudal SMC ASG320F-01-08S, 8mm x 1/8 plg
    Regulador de caudal SMC ASG320F-01-08S, 8mm x 1/8 plg
  • Schneider Electric AS-B846-002 AS B846 I_O ANALOG MULTIPLEXER CURRENT MODULE - 984 Series
    Schneider Electric AS-B846-002 AS B846 I_O ANALOG MULTIPLEXER CURRENT MODULE - 984 Series
  • Allen-Bradley PANEL PC, DC POWERED
    Allen-Bradley PANEL PC, DC POWERED
  • Allen-Bradley BARRIER,SHUNT DIODE
    Allen-Bradley BARRIER,SHUNT DIODE
  • XPSMC32Z Schneider Electric
    XPSMC32Z Schneider Electric

Random Products
  • Sensor de 200A, diámetro 17 mm.
    Sensor de 200A, diámetro 17 mm.
  • GP006127
    GP006127
  • 3M DBI-SALA Rollgliss R550 Rescue System, Length 10.0 m, 3329010
    3M DBI-SALA Rollgliss R550 Rescue System, Length 10.0 m, 3329010
  • 3M DBI-SALA Rollgliss R550 Rescue System, Length 10.0 m, 3329010
    3M DBI-SALA Rollgliss R550 Rescue System, Length 10.0 m, 3329010
  • V100 2.6 MW VCS V100 2.6 MW VCS
    V100 2.6 MW VCS V100 2.6 MW VCS

REQUEST QUOTES

Nombre no disponible.

In compliance with the Organic Law on the Protection of Personal Data 15/1999 of December, we inform you that your data is included in a file owned by ADJ DiTec Málaga S.L., duly registered in the General Registry of the Spanish Agency for Data Protection and will only be used to provide you with information about our services. In no case will these data be used for other purposes than those mentioned, nor will they be delivered to third parties, in accordance with the principles of data protection of Law 15/1999 of December 13, on the protection of personal data. If you do not wish to receive more commercial information, please let us know using this same communication channel, by writing to ADJ DiTec Málaga S.L., with a registered address at MALAGA (MALAGA), C.P. 29006, C/ Bodegueros 21, Local 4, or by email to the address info@adjditec.com.Get more information about our Privacy Policy

Newsletter

Enter your email to subscribe.

Successfully registered! You have been added to our newsletter.

Contact.

  • Address Calle Río Sil, 63, 29196 Málaga

  • Phone (+34) 951 152 505

  • Email info@adjditec.com

Follow us.

© Copyright. 2008 - 2025 All rights reserved.

We request your permission to obtain statistical data about your browsing activity on this website. Accept. | More information.